<?xml version="1.0"?>
<oembed><version>1.0</version><provider_name/><provider_url>https://lightingrecipe.com/de</provider_url><author_name>LRS Admin</author_name><author_url>https://lightingrecipe.com/de/author/77026pwpadmin/</author_url><title>What Exactly Does Blue Light Harm? -</title><type>rich</type><width>600</width><height>338</height><html>&lt;blockquote class="wp-embedded-content" data-secret="Yf4syrazm3"&gt;&lt;a href="https://lightingrecipe.com/de/what-exactly-does-blue-light-harm/"&gt;What Exactly Does Blue Light Harm?&lt;/a&gt;&lt;/blockquote&gt;&lt;iframe sandbox="allow-scripts" security="restricted" src="https://lightingrecipe.com/de/what-exactly-does-blue-light-harm/embed/#?secret=Yf4syrazm3" width="600" height="338" title="&#x201E;What Exactly Does Blue Light Harm?&#x201C; &#x2013; " data-secret="Yf4syrazm3" frameborder="0" marginwidth="0" marginheight="0" scrolling="no" class="wp-embedded-content"&gt;&lt;/iframe&gt;&lt;script&gt;
/*! This file is auto-generated */
!function(d,l){"use strict";l.querySelector&amp;&amp;d.addEventListener&amp;&amp;"undefined"!=typeof URL&amp;&amp;(d.wp=d.wp||{},d.wp.receiveEmbedMessage||(d.wp.receiveEmbedMessage=function(e){var t=e.data;if((t||t.secret||t.message||t.value)&amp;&amp;!/[^a-zA-Z0-9]/.test(t.secret)){for(var s,r,n,a=l.querySelectorAll('iframe[data-secret="'+t.secret+'"]'),o=l.querySelectorAll('blockquote[data-secret="'+t.secret+'"]'),c=new RegExp("^https?:$","i"),i=0;i&lt;o.length;i++)o[i].style.display="none";for(i=0;i&lt;a.length;i++)s=a[i],e.source===s.contentWindow&amp;&amp;(s.removeAttribute("style"),"height"===t.message?(1e3&lt;(r=parseInt(t.value,10))?r=1e3:~~r&lt;200&amp;&amp;(r=200),s.height=r):"link"===t.message&amp;&amp;(r=new URL(s.getAttribute("src")),n=new URL(t.value),c.test(n.protocol))&amp;&amp;n.host===r.host&amp;&amp;l.activeElement===s&amp;&amp;(d.top.location.href=t.value))}},d.addEventListener("message",d.wp.receiveEmbedMessage,!1),l.addEventListener("DOMContentLoaded",function(){for(var e,t,s=l.querySelectorAll("iframe.wp-embedded-content"),r=0;r&lt;s.length;r++)(t=(e=s[r]).getAttribute("data-secret"))||(t=Math.random().toString(36).substring(2,12),e.src+="#?secret="+t,e.setAttribute("data-secret",t)),e.contentWindow.postMessage({message:"ready",secret:t},"*")},!1)))}(window,document);
//# sourceURL=https://lightingrecipe.com/wp-includes/js/wp-embed.min.js
&lt;/script&gt;</html><description>From photobiological safety to eye-protection marketing: a comprehensive explanation Light and Health &#xB7; A Scientific Explanation Includes an analysis of Chinese standards for reading and writing desk lamps. Reference verification date: October 28, 2026 Buying a desk lamp, a pair of glasses, or even a screen protector today, you may encounter the same warning: &#x201C;You need protection against blue light.&#x201D; As a result, one part of the light spectrum has gradually been portrayed as an enemy of the eyes; a safety test report has been presented as proof of myopia prevention; and light that should be moderately reduced at night has been marketed as something that should be minimized at all times. The issue is not whether blue light can cause harm. It can, and decades of research and standards support that conclusion. The real questions are: Can the actual mechanisms of injury prove that everyday use presents the same risk? Even if a risk exists, has a particular product demonstrated that it provides effective protection? Each of these three questions requires evidence. Overmarketing most often occurs when the reasoning in between is omitted, jumping directly from &#x201C;potential harm&#x201D; to &#x201C;you need to buy this product.&#x201D; 01. First, distinguish three different issues: injury, discomfort, and physiological responses &#x201C;Light affects the eyes&#x201D; is a broad concept that encompasses at least three different issues. First: tissue damage. Examples include retinal photochemical or thermal injury caused by excessive ultraviolet radiation or intense light. This is the central concern addressed by photobiological safety standards. Second: visual discomfort. Examples include glare, reflections, and fatigue or dryness caused by prolonged close-up work. The discomfort is real, but discomfort alone does not establish that blue light has damaged the retina. Third: physiological regulation. Light influences alertness, melatonin, and the body&#x2019;s circadian clock. These effects may be beneficial or may interfere with sleep when they occur at inappropriate times. Calling all three &#x201C;blue-light eye damage&#x201D; is like treating burns, glare, and an alarm clock ringing as the same thing. The analogy does not imply that their mechanisms are identical; it reminds us that different outcomes require different assessment methods. [1][2][3] 02. Why light can genuinely cause harm The eye is not simply a passive pane of glass receiving light. The cornea, crystalline lens, and retina absorb different wavelengths, while the eye&#x2019;s optical system focuses incoming light to form an image. When the absorbed optical energy exceeds the tissue&#x2019;s tolerance under particular exposure conditions, damage may occur. Two important pathways are thermal effects and photochemical effects. Thermal effects are associated with temperature increases following energy absorption. Photochemical effects involve chemical reactions initiated by light that may damage cellular structures. The term blue-light hazard primarily refers to the risk of the latter occurring in the retina. [1][2] Therefore, the fact that &#x201C;blue-light photons have relatively high energy&#x201D; provides only physical background; it cannot, by itself, establish that harm will occur. Whether tissue absorbs the light, how much it absorbs, how the energy is distributed, and how long exposure lasts all affect the outcome. Blue light does not suddenly become toxic at one particular wavelength. Standards use the blue-light hazard weighting function, B(&#x3BB;), to weight actual spectral radiation according to the relative effectiveness of different wavelengths in producing this type of injury. The CIE states that the spectral sensitivity of this hazard peaks at approximately 435&#x2013;440 nm. [1] In other words, laboratory calculations do not simply measure &#x201C;what percentage of the light is blue.&#x201D; They calculate weighted optical radiation associated with a specific injury mechanism. 03. The existence of a hazard does not mean your everyday use carries the same risk A cup of hot water and a cup of warm water can both transfer heat to the skin, but that does not mean they present the same risk of burns upon contact. Light works the same way. An assessment must specify at least the following: the spectrum, the amount of radiation emitted or received, the viewing direction, the apparent size of the light source in the field of view, and the duration of exposure. This explains why damage observed in cell or animal experiments cannot automatically be translated into the claim that &#x201C;the LED lights in your home are damaging your eyes.&#x201D; Cells in a culture dish do not have the optical and protective features of a complete eyeball. Animal eyes, activity patterns, and exposure arrangements may also differ from those of humans. These studies help identify mechanisms, but determining whether they represent everyday risks requires comparing experimental doses with actual exposure levels. In its 2019 position statement, the CIE specifically cautioned against extrapolating from conditions involving excessive exposure, fixed staring, nocturnal animals, or isolated cells. Its assessment of general white-light illumination was that, under reasonably foreseeable conditions of use, practical assessments did not exceed the blue-light hazard exposure limits. [1] This conclusion has a defined scope. Sunlight, welding arcs, intense blue-light sources, and equipment designed for specialized applications must still be managed according to their actual exposure conditions. Science does not deny that hazards exist. It puts those hazards back into the right context. 04. What is the scientific basis of safety standards? Photobiological safety standards were not hastily created after someone noticed a blue peak in LED emissions. Long before LEDs became widespread, researchers had been studying retinal damage caused by different wavelengths, intensities, and exposure durations. In 1976, Ham, Mueller, and Sliney published a study in Nature examining retinal responses in rhesus monkeys under multiple monochromatic wavelengths and investigating the differences between thermal and photochemical effects. It remains a classic work in the history of this research. [4] Subsequent exposure limits were developed by combining experimental findings, observations of injury, and biophysical models. The ICNIRP then established protective limits based on injury thresholds and uncertainty, rather than simply adopting the lowest observed injury dose as the safety threshold. [2] Two points are important here. First, exceeding an exposure limit does not mean that injury will occur immediately or inevitably. It means that the exposure can no longer be considered acceptable under the protection framework provided by that limit. Second, remaining below a limit does not mean a lamp receives a perfect score in every respect, including comfort, sleep, visual quality, or individual special circumstances. Safety limits address specific injury risks. They should not be expanded into a guarantee of every possible health benefit. 05. How are laboratory measurements actually performed? Photobiological safety testing of mass-produced products generally does not involve repeating animal experiments for every lamp model. Instead, the product&#x2019;s optical radiation is measured and compared with the applicable standards and limits. The basic procedure includes confirming the product&#x2019;s operating and output conditions, setting the assessment distance and direction, measuring the spectrum, selecting the appropriate hazard weighting function, and accounting for exposure duration, field of view, source size, and measurement uncertainty. [5] The most easily overlooked question is: What exactly is being measured? Illuminance, measured in lux, is weighted according to the human eye&#x2019;s photopic sensitivity. It primarily indicates how much visually effective light reaches a surface. Blue-light hazard-weighted irradiance, Eb, is generally measured in W/m&#xB2;. Blue-light hazard-weighted radiance, Lb, is measured in W/(m&#xB2;&#xB7;sr). The latter incorporates direction and solid angle, making it particularly relevant to assessments of retinal image-related risks. Two lamps may illuminate a desktop equally brightly while having completely different emitting-surface sizes, local luminance levels, and direct-viewing conditions. Therefore, &#x201C;the desktop receives 500 lux&#x201D; cannot, by itself, establish whether looking directly at the lamp is safe. Nor can Eb and Lb be converted into one another simply by comparing their units. Their relationship depends on the source&#x2019;s angular distribution and measurement geometry. A reading in W/m&#xB2; cannot be directly compared with a limit expressed in W/(m&#xB2;&#xB7;sr). [2][5] The real value of a test report lies not only in its final classification but also in all the conditions that make that conclusion valid. 06. What do RG0, RG1, RG2, and RG3 actually mean? IEC 62471:2006 uses risk groups. For the blue-light hazard posed by continuous light sources, the traditional classification uses the following time bases: These times are assessment benchmarks used for classification. They are not recommended staring durations, nor are they countdowns indicating that injury will inevitably occur when the time expires. Different hazard categories also use different time bases. [6] The safety concept behind RG1 incorporates limits on exposure associated with normal human behavior. RG2 takes account of natural avoidance responses to intense visual stimuli. Actual products must still satisfy the relevant use and protection requirements; these behavioral responses should not be treated as encouragement to stare directly at a light source. [6] Therefore, RG0 does not mean &#x201C;contains no blue light,&#x201D; and it does not mean &#x201C;prevents myopia.&#x201D; Achieving RG0 for the blue-light hazard also does not automatically establish that every other photobiological hazard is exempt. Similarly, RG1 is not synonymous with a &#x201C;toxic lamp.&#x201D; To interpret a classification correctly, the applicable standard, distance, intended use, and test conditions must all be considered. 07. What has changed between the old and new standards? Three documents with different purposes are often confused with one another. IEC 62471:2006 is the foundational standard that remains in force. It provides the exposure limits, measurement framework, and classification system for photobiological safety. [7] IEC TR 62778:2014 is a technical report on applying blue-light hazard assessment to light sources and luminaires. It was withdrawn on May 26, 2023. [8] IEC 62471-7:2023 addresses light sources and luminaires primarily emitting visible radiation for lighting or signaling. It uses an assessment approach tied to the product and its application, producing a pass-or-fail result for a specified intended use. [9] The newer edition has not overturned the scientific basis of photochemical injury. Instead, it asks additional practical questions: Where is this lamp intended to be used? At what distance, and in what way, will people be exposed to its light? Its blue-light assessment uses application groups such as BLH-A, BLH-B, and BLH-C, together with their corresponding conditions. For example, portable lamps intended for children and ordinary desk lamps have different application requirements. These letter designations cannot be directly converted into RG0, RG1, or RG2. [10] Thus, it is incorrect to say that &#x201C;all the old RG classifications are obsolete.&#x201D; It is equally incorrect to rely on an RG0 result alone to claim compliance with every requirement of the newer standard. The appropriate assessment pathway for a product must still be determined by checking the relevant product safety standard and the version referenced by the market in which the product is sold. 08. Where does RG0 for Chinese reading and writing desk lamps come from, and how does it align with international standards? In the Chinese market, &#x201C;RG0,&#x201D; &#x201C;National AA,&#x201D; and &#x201C;complies with myopia-prevention standards&#x201D; are often displayed together in advertisements. This can lead consumers to believe that all three labels jointly prove a lamp can prevent myopia. In fact, they address different questions. Scientific origins China&#x2019;s GB/T 20145-2006, Photobiological Safety of Lamps and Lamp Systems, is identical to CIE S 009/E:2002. IEC 62471:2006 also originated from the same CIE standard. The assessment of blue-light hazards in Chinese reading and writing desk lamps is therefore not based on an entirely separate theory of eye damage; it rests on a shared international foundation for photobiological safety. [7][16] Application methodology GB/Z 39942-2021, Application of GB/T 20145 for the Assessment of Blue Light Hazard of Light Sources and Luminaires, is identical to IEC TR 62778:2014. This approach connects the measurement, assessment, and transfer of blue-light hazard data for light sources and luminaires. [17] China has also introduced specific requirements for reading and writing desk lamps. GB/T 9473-2022, Performance Requirements for Reading and Writing Desk Lamps, took effect on January 1, 2024, replacing the 2017 edition. Clause 5.9 requires the retinal blue-light hazard classification to be RG0, with the assessment based on GB/Z 39942-2021. Publicly available China Quality Certification Centre (CQC) performance certification rules also specify this clause and its test method. [18][19][23] GB 40070-2021, Health Requirements for Myopia Prevention and Control in School Supplies for Children and Adolescents, took effect on March 1, 2022. It is a mandatory national standard. For reading and writing desk lamps within its scope that are not exempt from retinal blue-light hazard assessment under the applicable luminaire standard, Clause 11.3 requires assessment according to IEC/TR 62778 and achievement of RG0. [20] The distinction between methodology and requirement is important. International foundational documents explain how to measure and classify. China&#x2019;s specific product and health standards further specify which classification a particular product category must achieve. Under these applicable requirements, RG0 is a compliance requirement. It does not, by itself, prove that a particular desk lamp offers additional clinically demonstrated eye-protection benefits. The presence of the words &#x201C;myopia prevention and control&#x201D; in a standard&#x2019;s title also does not mean that every individual requirement in that standard has been validated as a treatment or prevention effect against myopia. The blue-light clause manages the risk of retinal photochemical injury. Claims that a product reduces the onset or progression of myopia still require evidence appropriate to those specific outcomes. &#x201C;National AA&#x201D; is not another blue-light hazard classification. The A and AA grades correspond to illuminance and illuminance uniformity requirements, whereas RG0 corresponds to blue-light hazard assessment. Neither can substitute for the other. [19] China has also adopted the newer international framework GB/T 30117.7-2026, Photobiological Safety of Lamps and Lamp Systems &#x2014; Part 7: Light Sources and Luminaires Primarily Emitting Visible Radiation, was published on February 27, 2026, and took effect on September 1, 2026. It is identical to IEC 62471-7:2023. [21] Accordingly, as of October 2026, the accurate situation is that the newer application-based assessment standard has been implemented, but the RG0 requirement in the existing product standard for reading and writing desk lamps, along with the assessment pathway it references, has not automatically disappeared merely because the newer standard was published. One particularly easy-to-misinterpret example concerns IEC TR 62778:2014. Although it has been withdrawn at the IEC level, its Chinese adoption, GB/Z 39942-2021, is still listed as current on China&#x2019;s official standards platform. Following a review on May 30, 2025, it was confirmed to remain in force. [8][17] Withdrawal of an international document does not automatically complete the revision of national standards or the transition of domestic certification systems. Conversely, the fact that a domestic document remains in force does not entitle manufacturers to describe it as the latest IEC assessment method. In addition, GB/T 30117.1-2024 took effect in November 2024 and modifies IEC 62471:2006. It must not be conflated with GB/T 20145-2006, which is identical to CIE S 009. China&#x2019;s official platform currently lists both as in force. &#x201C;Modified adoption&#x201D; must not be described as &#x201C;identical adoption.&#x201D; [16][22] Genuine alignment with international standards requires checking each level: the shared scientific foundation, the test-method version adopted, the intended product use, the assessment distance and field of view, and the specific requirements of the market in which the product is sold. The RG0 result obtained through the older pathway cannot be directly converted into a BLH application group under the newer standard. Nor can passing the newer assessment, by itself, replace the existing RG0 requirement for Chinese reading and writing desk lamps. Without aligning the measurement methods and application conditions, comparing the letters or numbers on two certificates cannot establish which certificate represents a &#x201C;stricter&#x201D; standard. For the Chinese market, responsible wording would be: &#x201C;This product complies with [a specified requirement] under [a specified standard], assessed under [specified conditions].&#x201D; That is more informative than a vague claim of having &#x201C;the highest international eye-protection rating.&#x201D; 09. Understanding instrument readings prevents numbers from becoming a new superstition Taking the Eb, Kbv, and RG fields displayed in the In. Licht Ultra interface as examples, their real value is to help people understand light under the measurement conditions&#x2014;not to turn every number into a health ranking. Eb is blue-light hazard-weighted irradiance. It describes the relevant weighted optical radiation received at the measurement position. It is neither a percentage of blue light nor a probability of injury. Kbv is the blue-light hazard-weighted radiation quantity per unit of luminous flux, usually expressed in W/lm. Under corresponding and consistent spectral and measurement conditions, it can be expressed as Eb divided by illuminance. [11][12] Suppose a light source has a Kbv value of 0.0005 W/lm and its spectrum remains unchanged: This is an illustrative calculation. It shows that even when the spectral proportion remains unchanged, exposure can increase as illuminance increases. It also demonstrates why comparing Kbv values alone cannot replace comparing actual exposure levels. These two numbers cannot, on their own, determine whether a product passes the newer application-based assessment. As for the RG value displayed by an instrument, its interpretation requires knowledge of the standard used, the algorithm, the geometric assumptions, and the applicable conditions. A single result displayed in an app cannot establish that the complete product-testing procedure required for compliance has been performed. Measurement is the starting point. Understanding what the data can actually tell you is what makes the assessment professional. 10. Why can light at night affect sleep without &#x201C;poisoning the retina&#x201D;? Light can influence the body&#x2019;s physiological clock without causing tissue damage. The retinal pathways involved in these responses include intrinsically photosensitive retinal ganglion cells containing melanopsin. These cells also integrate information from other photoreceptors. CIE S 026:2018 provides a measurement framework for this type of photoreceptor-driven response, but it is not a photobiological safety standard and cannot fully predict an individual&#x2019;s sleep response. [3] Therefore, mel-EDI can help describe the degree of stimulation of the melanopsin system, but it cannot be used directly as a measure of eye damage. Even if the same numerical value is recorded during the day and before bedtime, the appropriate lighting objectives may differ. The CIE&#x2019;s 2024 integrative lighting position statement cites recommendations for healthy young adults that include higher light exposure during the day, substantially reducing exposure during the three hours before bedtime, and keeping the sleeping environment close to darkness, while also accounting for glare and other lighting needs....</description><thumbnail_url>https://lightingrecipe.com/wp-content/uploads/2026/10/1-2.png</thumbnail_url><thumbnail_width>1920</thumbnail_width><thumbnail_height>819</thumbnail_height></oembed>
